Fault Passage Indicators - Line Indicators Nortroll
 
 
  LineTroll 3100 6-400KV fault-indicator for overhead power lines      
 
Programmable operating parameters

●  High visibility ( > 10 lumens)
●  Usable on all Medium Voltage distribution/sub transmission networks 6-400 kV.
●  Two models, model LT 3100D for distribution 6-66kV and model LT 3100T for
●  sub-transmission 66-400 kV. Dual indications (permanent and transient faults)
●  Display unity can rotate for maximum visibility.
●  Built in log and fault counter.
●  Resistant to tough weather conditions
●  Battery backed clock calendar
●  Communication modules available for scada integration and rtu.
●  316 Stainless Steel & PTFE wetted parts
●  1/8" Resistant to tough weather conditions
●  
Battery capacity monitoring.



 

 
 

LineTroll 111K - Utility pole mounted fault indicator for  6-66KV transmission lines


THE MONEY-SAVER
Minimize duration of blackouts. Reduce number of fault reclosures, reduce wear and tear. Works with single- and 3-phase line configurations.

VERSATILE
User configuration of fault sensitivity, trip and reset parameters. Extended reset time with low-power LED indication. Automatically adapts to load current (di/dt). Optional output relay contacts for connection with RTU’s and HMI.

EASY TO MOUNT
Mount the indicator 3m below transmission lines. No special tools required. Reducing the total mounting costs.

HIGH VISIBILITY
Omni directional Xenon tube flash-light. Specially designed lens for easy long distance monitoring.

HOW IT WORKS:
Linetroll 111K contains magnetic and electric field sensors - sensing line current and line voltage. The magnetic sensor automatically adapts to line current, when di/dt increase rapidly the sensor will detect the overcurrent. The electric field sensor also monitor the presence of voltage potential. The sensor signals are processed and compared with a set of alarm criteria's configured by the user.
When a line fault (that fulfills the alarm criteria) occurs, all indicators installed between the feeding point and the fault location will signal an alarm.
A Xenon light indicates the passing fault current by releasing a omni-directional high intensity flash.

INSTALLATION:
Linetroll 111K is fitted on a utility pole 3 - 5 m below transmission lines, check the User Guide for details.
Linetroll 111K mounts with screws (included) or wrapping bands.
Linetroll 111K is easily tested with a magnet after installation.

TECHNICAL SPECIFICATIONS

Detection:
Short Circuits: Isc > 2 * Iload.
Earth Faults: Sensitivity set by user: maximum 4A.
Note: these are approximate values. For detailed information, check Linetroll 111K User Guide.

Indication:
Omni-directional Xenon flash unit.
Discharge energy 0,2 Joule.
Flashing frequency: 7 -12 flashes/min.
Extended indication time through flashing LED

Ignores Inrush Current:
To avoid detection of inrush current, the indicator is blocked for 3 seconds after reenergizing.

Ambient temperature:
-40oC to +70oC.

Power supply:
3,6V 13Ah Lithium battery.

Weight:
750 grams including mounting bracket.

Optional:
Mounting/testing tool for hot-stick.
Relay contact kit for remote indication through the comtroll system.

 

 
 
 

LineTroll 110Eμr Fault Passage Indicator for overhead lines (6-69 [kV])


A cluster of red LED's for permanent fault and one green LED for transient fault. In addition a single LED will give indication on low battery status. High visibility.

●  Programmable operating parameters.
●  High visibility ( > 12 lumens) 360 degrees.
●  Usable on all Medium Voltage distribution networks 6-69 [kV].
●  sub-transmission 66-400 kV. Dual indications (permanent and transient faults)
●  Usable on multi circuit systems.
●  Voltage or current as start criteria (programmable) = inrush blocking.
●  Resistant to tough weather conditions
●  Dual indication, permanent and transient faults.
●  Resistant to tough weather conditions.
●  Battery capacity monitoring.

Functional description:

LineTroll 110Eμ continuously monitors the line voltage and phase current, the sources of information it needs to operate. The unit is fully self-contained, no external transformers or connections is required. During normal line conditions, LineTroll 110Eμ remains extinguished.
The indicator is looking for a specific sequence of line conditions to happen before it starts flashing. The general sequence is as follows:
A. The line should be energised (voltage or current present) for a minimum of 5 seconds.
B. Di/Dt : The line current should increase rapidly by the amount of a user set value (the step level). Treshold, the line current exceeding a present current level.
C. The line should be de-energised. (Voltage or current not present).
The user may program the criteria for operation to suit his local requirements by manipulating a bank of micro-switches inside the indicator.

Note: Voltage or current as start and stop criteria is user programmable.

Application:

Short circuit and Earth fault indication for overhead lines.
System voltage: 6-69 [kV] medium voltage networks.
Grounding system: Isolated, resistor and solidly grounded.

Fault detection:

Sensitivity Di/Dt, 50[Hz]: 6, 12, 25, 60 or 120 [A] *
Sensitivity Treshold, 50[Hz]: 250, 500, 750 or 1000 [A] *
Duration: > 60 [ms] (20[ms] on request)
Inrush blocking: 5 sec.
CB-Tripping: Within 5 sec.

Reset:
Automatic: Re-energised line (Voltage or current, programmable)
Timer: 2, 6, 12 or 24 hours *
Manual: By magnet / Mounting reset tool
Note*: All tresholds, timers etc. are selectable and programmable by dip-switches.

Indication:
Permanent faults: 4 red and 1 green LED.
Transient faults: 1 green LED.
Intensity: > 12 lumens for permanent faults.
Visibility:
  Day:   250[m]
  Night:  2 [km]
  Direction: 360 degrees
Flashing frequency: f = 0.2 [Hz], after 12 h reduced to f=0.1 [Hz].
Low battery indication: 1 LED (f=0.1 [Hz]).

Power Supply:
1 Lithium cell: D-size total capacity 16.5 [Ah]
Battery change: every 1500 flash hours, normal conditions every 7-8 years.

Mounting:
Hot-stick: Live line mounting with KBN-3 mounting tool.
Conductor size: 5-24 [mm]

Temperature: - 40 to +85 [C]

Housing: Polycarbonate, UV stabilized.
Dimension: 202 x 54 [mm] (with box, 235x65x85)
Weight: 460 [g] (Box and battery included)
Degree of protection: IP54

 

 

 


   
 

LineTroll 110 Tµ(r) Fault passage indicator for overhead lines (66-138kV)


Product number LineTroll 110 Tµr: 04-1200-13
Product number LineTroll 110 T
µr, exluded corona trap: 04-1200-15
Product number replacement battery KB 111: 1056

LineTroll 110 Tµ(r) Fault indicates earth- and shortcircuit - faults by detection of changes in the magnetic field set up by the fault current. The indicator can detect and independently indicate both permanent and transient faults. A cluster of red LED's for permanent fault and one green LED for transient fault.  An orange LED will give indication of low battery status. Hig visibillity.

Features Linetroll 110Tµ(r):

Programmable operating parameters.
High visibility (>12 lumens)
Usable on all Sub-Transmission voltage distribution networks 66-138 kV.
Usable on multicircuit systems.
Voltage or current as start criteria (programmable)
Dual indications (permanent and transient faults)
Resistant to tough weather conditions
Battery capacity monitoring
Special version LT-110 Tµr is available with integrated radio for SCADA monitoring.

Functional Description

LineTroll 110Tµ continuously monitors the line voltage and phase current, the sources of information it needs to operate. The unit is fully self-contained, no external transformers or connections is required. During normal line conditions, LineTroll 110Tµ remains extinguished.

The indicator monitors for a specific sequence of line conditions to happen before it starts flashing. The general sequence is as follows:

A. The line should be energised (voltage or current present) for a minimum of 5 seconds.
B. Di/Dt: The line current should increase rapidly by the ammount of a user set value (step level). Treshold: The line current exceeding a preset current level.
C. The line should be de-energised (voltage or current not present).

The user may program the conditions for operation to suit his local requirement by manipulating a bank of DIP-switches inside the indicator.

Note: Voltage or current as a start and stop criteria is user programmable.

Technical Specifications:

Application:
Short circuit and Earth fault indication for overhead lines.
System voltage: HV-Distr. - and transmission lines (66-138[kV])
Grounding system: Resistor and solidly grounded.

Fault-detection:
Sensitivity Di/Dt: 500, 1000 [A]
Sensitivity threshold: 500, 1000 [A]
Duration: >60 ms (20 ms on request)

Inrush blocking: 5 seconds.

Reset:
Automatic:
Re-energized line (voltage or current)*.
A) minimum reset current: 50 [A]or
B) minimum reset voltage: 50 [kV]
Timer: 2, 6, 12 or 24 hours*
Manual: By magnet (remotely for LT-110Tµr)

*:User programmable DIP-switches.

Indication:
1 Green LED for transient fault.
4 Red LED's for permanent fault.
1 Red/orange LED for low battery indication.
Intensity: >12 lumens.

Power supply:
Battery change: every 1200 flash hours, norm. every 7-8 years.

Mounting:
Hot-stick: Live-line mounting with shotgun hot stick.
Conductor size: 5-36 [mm].

Temperature:
-40 to +85 degrees celcius.

Housing:
Material: Polycarbonate, UV-stabilized.
Line-Clutch: Polyamide.
Dimension: 235 x 158 [mm].
Weight: 482 [g]
Protection class: IP 54.

Packaging information:
Number of units each kit: 3 units.
Dim. box with units: 165 x 260 x250 [mm].
Weight (3 units): 1635 [g].

Special version:
LT-110 Tµr: Integrated 2,4 [GHz] radio.
Datarate/messages: 250 [kbps] Fault and status (battery and comm.).
Tx Power /Rx sens: 1 [mW] / -90 [dBm].
Range: > 20 m LoS (margin 20 [dB]).
Concentrator: Nortroll's CmT 110C /115 C.


 

 




 
 

 
 
     